    all iam asking for is if u can help me each one of u can transitalte at least 5 pages for me and thier are not that long but they are hard they are medical and arcaticures an stuff like that and i hope u all can help me i will attach here one page so u know what iam talking about ok .................................
    ok here but pleasee do reply to me cuz i really dont have much time.....


    )))))))))))))))))))))))))))))))))))))))))))))))))))))))))

    X-Ray System,Radiograohic / Flouroscopic over table Rad 0026
    QTY: 1
    Remote-control radiology table:
    X-ray table:
    • ± (90°) table tilting movement.
    • Adjustable source to image distance (115-150) cm.
    • (up/down) movement at horizontal position with reasonable distance.
    • X-ray source angulations +/– (40) ° at minimum distance.
    • I.I or (Receptor unit) with (40) cm size (without cassette operation) and (3) zoom level.
    • Tabletop movement (longitudinal and transverse) with reasonable distance.
    • Patient weight up to 150 kg.
    • Remotely controlled compression device with detachable cone arm.
    • Lower and upper radiation protection.
    • Examination lamp with ceiling mounting.
    • Intercom system for communication between examination room and control room.
    • Arm holder for assisting in the patient's lateral arm positioning.
    • Bracket arm and belt compressor.
    X-ray generator:
    • High frequency x-ray generator with multiples voltage (40-150) KV range and (80) kw power.
    • (3, 2, 1 and zero) point technique must be available.
    • Measuring dose system for (dose area product) with printer.
    • Organ programs (full option).
    • Pulsed fluoroscopy with (3, 7.5, and 15) pulse/sec.
    • Digital background storage during the fluoroscopic scene.
    • Radiation-free display of the collimator in the last image hold (LIH) on TV monitor.
    • Contrast gain for critical display fields through digital adaptation of the gray value range.
    X-ray tube:
    • Dual focal spot x-ray tube with (150) kv nominal voltage.
    • Anode drive with (3 phase current) and high rpm.
    • Total filtration (2.5) mm Al.
    TV camera and CCU:
    • High resolution x-ray camera with CCD sensor.
    • Constant image brightness due to ADR and AVR.
    • High contrast and high spatial resolution, noise reduction, and flicker-free image display.
    • Two high resolution monitors.
    Image processing unit:
    • Acquisition speed up to (8) frames/sec.
    • Acquisition matrix (1024)².
    • High capacity hard disk.
    • CD or DVD recorder in dicom format.
    • Dicom send and dicom read.
    • Display of R/L marks.
    • Display of the dose-area product measured on the monitor.
    • Manual storage, post processing and documentation of fluoroscopic images and exposures.
    • Noise reduction, edge enhancement with digital continuous fluoroscopy.
    • Image post processing such as zooming, roaming, electronic shutters, annotation, measuring
    angles…….ect.
    Additional:
    • Foot switch for fluoroscopy and radiography.
    • Remote control for the entire image processing functions.
    • Foot holder, Knee supports(R/L), and Hand grip.
    • Chest stand module for the same over-table x-ray tube.